@article{oai:fukuyama-u.repo.nii.ac.jp:00008740, author = {Inoue, Hirofumi and Harada, Takuya and Eto, Seiji and Nakashima, Ken and Ibusuki, Takuya and Kosha, Keiko and Date, Yuuko and Sanematsu, Emiko and Shinohara, Yoshitake and Takahashi, Kojiro and Yoshimura, Reiji and Nakamura, Jun and Kojima, Eijiro and Tsuruta, Yasuto}, issue = {32}, journal = {福山大学薬学部研究年報, Annual report of the Faculty of Pharmacy & Pharmaceutical Sciences, Fukuyama University}, month = {Dec}, note = {The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high-performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o-phthalaldehyde, paroxetine was derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed-phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within-day and day-to-day relative standard deviations were 3.0-3.4 and 2.7-8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal-to-noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring., The therapeutic drug monitoring of paroxetine could be used to optimize the pharmacological treatment of depressed patients. A simple and sensitive high-performance liquid chromatography procedure was developed for the determination of paroxetine in serum. After simple pretreatment of serum (50 μL) with acetonitrile and o-phthalaldehyde, paroxetine was derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride at 70°C for 20 min in borate buffer (0.1 mol/L, pH 8.0) to produce a fluorescent product. The derivative was separated on a reversed-phase column at 40°C for stepwise elution with (A) acetic acid (10 mmol/L) and (B) acetonitrile. The flow rate was 1.0 mL/min. The fluorescence intensity was monitored at excitation and emission wavelengths of 320 and 400 nm, respectively. The within-day and day-to-day relative standard deviations were 3.0-3.4 and 2.7-8.3%, respectively. The detection limit of paroxetine was 8.3 fmol at a signal-to-noise ratio of 3. As the proposed method that only requires a small quantity of serum (50 μL) is simple, sensitive and reproducible, it would be useful for clinical and biochemical research as well as drug monitoring.}, pages = {29--30}, title = {血清中パロキセチンの簡便な前処理による蛍光プレラベルHPLC分析法(発表論文抄録(2013))}, year = {2014} }