{"created":"2023-06-19T09:51:12.279109+00:00","id":8262,"links":{},"metadata":{"_buckets":{"deposit":"a5adb759-19e4-43f4-9518-d1a23f068899"},"_deposit":{"created_by":3,"id":"8262","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8262"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00008262","sets":["502:505:675:714"]},"author_link":["44432","44433","44431"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"76","bibliographicPageStart":"69","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮内, 克之"}],"nameIdentifiers":[{"nameIdentifier":"44431","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Shear failure test was performed for RC beams strengthened with carbon fiber grid reinforcement and polymer cement mortar by drying spray system. Based on the test results, effectiveness of carbon fiber grid reinforcement for the proposed strengthening method was evaluated quantitatively from the points of both shear carrying capacity and the strain of the carbon fiber grid. It was cleared that the proposed method was very applicable for seismic strengthening of existing RC members. It was found that coefficient of effectiveness of carbon fiber grid reinforcement for the proposed seismic strengthening was at least 70%.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44432","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ミヤウチ, カツユキ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44433","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MIYAUCHI, Katsuyuki","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Civil and Environmental Engineering, Faculty of Engineering, Fukuyama University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部建設環境工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2006-12-01"}],"displaytype":"detail","filename":"KJ00005781677.pdf","filesize":[{"value":"954.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/8262/files/KJ00005781677.pdf"},"version_id":"0210021a-d367-48f7-87ea-eebb214fb7b4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"耐震補強","subitem_subject_scheme":"Other"},{"subitem_subject":"補強","subitem_subject_scheme":"Other"},{"subitem_subject":"炭素繊維グリッド","subitem_subject_scheme":"Other"},{"subitem_subject":"乾式吹付け","subitem_subject_scheme":"Other"},{"subitem_subject":"Seismic Strengthening","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Strengthening","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Carbon Fiber Grid","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Drying Spray System","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"乾式吹付けとの併用による耐震補強方法における炭素繊維グリットの有効率について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"乾式吹付けとの併用による耐震補強方法における炭素繊維グリットの有効率について"},{"subitem_title":"Effectiveness of Carbon Fiber Grid Reinforcement for Seismic Strengthening of Existing RC Members","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["714"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-12-01"},"publish_date":"2006-12-01","publish_status":"0","recid":"8262","relation_version_is_last":true,"title":["乾式吹付けとの併用による耐震補強方法における炭素繊維グリットの有効率について"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:26:59.759376+00:00"}