{"created":"2023-06-19T09:51:11.681518+00:00","id":8248,"links":{},"metadata":{"_buckets":{"deposit":"a35c6121-6eb4-4882-9958-fef19e7abc71"},"_deposit":{"created_by":3,"id":"8248","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8248"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00008248","sets":["502:505:675:713"]},"author_link":["44381","44387","44384","44379","44389","44382","44380","44378","44386","44383","44385","44388"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"330","bibliographicPageStart":"325","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"木村, 純壮"}],"nameIdentifiers":[{"nameIdentifier":"44378","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤, 大樹"}],"nameIdentifiers":[{"nameIdentifier":"44379","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"奥家, 隆史"}],"nameIdentifiers":[{"nameIdentifier":"44380","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大塚, 健太"}],"nameIdentifiers":[{"nameIdentifier":"44381","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"In the field of physical education studies, kinematics, occupational therapy studies, physical motor function has been measured, and has been evaluated. In the field of engineering, physical exercise property has been analyzed dynamically, and a biolocomotion system has been identified for development of myoelectric prosthetic hand. But, quantitative evaluation is necessary, and, as for the study contents, there is limitation in scope and field of application. In this paper, mechanism of finger flexure and extension exercise is aimed at, driving force and EMG of a flexor and an extensor are considered, system model of 2 input 1 output is introduced, and system identification is done for the basics. The results of identification are effective and the estimated system model can expect wide application in the field of medical service rehabilitation and sports biomechanics and so on.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44382","nameIdentifierScheme":"WEKO"}],"names":[{"name":"キムラ, ジュンソウ"}]},{"nameIdentifiers":[{"nameIdentifier":"44383","nameIdentifierScheme":"WEKO"}],"names":[{"name":"イトウ, ダイキ"}]},{"nameIdentifiers":[{"nameIdentifier":"44384","nameIdentifierScheme":"WEKO"}],"names":[{"name":"オクイエ, タカシ"}]},{"nameIdentifiers":[{"nameIdentifier":"44385","nameIdentifierScheme":"WEKO"}],"names":[{"name":"オオツカ, ケンタ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44386","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KIMURA, Junso","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44387","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ito, Daiki","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44388","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Okuie, Takashi","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"44389","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Otsuka, Kenta","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical System Engineering, Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical Engineering, Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical Engineering, Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Department of Mechanical Engineering, Faculty of Engineering, Fukuyama University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部機械システム工学科"},{"subitem_text_value":"福山大学工学部機械工学科:(現)興新設計"},{"subitem_text_value":"福山大学工学部機械工学科:(現)三和設計(株)"},{"subitem_text_value":"福山大学工学部機械工学科:(現)石井表記(株)"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2005-12-01"}],"displaytype":"detail","filename":"KJ00005781663.pdf","filesize":[{"value":"654.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/8248/files/KJ00005781663.pdf"},"version_id":"21a0bca6-a383-4887-bb9f-69d8ec0de5c4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"システム同定","subitem_subject_scheme":"Other"},{"subitem_subject":"EMG","subitem_subject_scheme":"Other"},{"subitem_subject":"手指運動","subitem_subject_scheme":"Other"},{"subitem_subject":"System identification","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"EMG","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"finger motion","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"屈筋と伸筋の筋電位を用いた繰返し法による手指屈曲伸展運動システムの基礎的同定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"屈筋と伸筋の筋電位を用いた繰返し法による手指屈曲伸展運動システムの基礎的同定"},{"subitem_title":"Basic System Identification for Finger Motion considering EMG of Flexor and Extensor Muscle","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["713"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-12-01"},"publish_date":"2005-12-01","publish_status":"0","recid":"8248","relation_version_is_last":true,"title":["屈筋と伸筋の筋電位を用いた繰返し法による手指屈曲伸展運動システムの基礎的同定"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:27:11.565780+00:00"}