{"created":"2023-06-19T09:51:10.202316+00:00","id":8213,"links":{},"metadata":{"_buckets":{"deposit":"8535f5e1-8f62-4405-9781-eb35e17ab0c1"},"_deposit":{"created_by":3,"id":"8213","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8213"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00008213","sets":["502:505:675:713"]},"author_link":["44132","44134","44133"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"66","bibliographicPageStart":"59","bibliographicVolumeNumber":"29","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮内, 克之"}],"nameIdentifiers":[{"nameIdentifier":"44132","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Cyclic loading test was performed for existent RC column strengthened with polymer cement mortar by drying spray system and carbon fiber grid reinforcement. It was cleared that the proposed method was very applicable for seismic strengthening of existent RC column. It was found that a necessary amount of carbon fiber grid reinforcement for the seismic strengthening was at least 0.15 %, and least thickness of the polymer cement mortar was about 30 mm.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44133","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ミヤウチ, カツユキ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44134","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MIYAUCHI, Katsuyuki","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Department of Civil and Environmental Engineering, Faculty of Engineering, Fukuyama University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部建設環境工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2005-12-01"}],"displaytype":"detail","filename":"KJ00005781628.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/8213/files/KJ00005781628.pdf"},"version_id":"7f5300ad-8024-4e8f-8de7-44bda535b613"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"耐震補強","subitem_subject_scheme":"Other"},{"subitem_subject":"補強","subitem_subject_scheme":"Other"},{"subitem_subject":"乾式吹付け","subitem_subject_scheme":"Other"},{"subitem_subject":"炭素繊維","subitem_subject_scheme":"Other"},{"subitem_subject":"RC柱","subitem_subject_scheme":"Other"},{"subitem_subject":"Seismic Strengthening","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Strengthening","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Drying Spray System","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Carbon Fiber","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"RC Column","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"乾式吹付け工法と炭素繊維グリットを併用した既存RC柱の耐震補強の可能性について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"乾式吹付け工法と炭素繊維グリットを併用した既存RC柱の耐震補強の可能性について"},{"subitem_title":"Seismic Strengthening of Existent RC Column with Polymer Cement Mortar and Carbon Fiber Grid Reinforcement","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["713"],"pubdate":{"attribute_name":"公開日","attribute_value":"2005-12-01"},"publish_date":"2005-12-01","publish_status":"0","recid":"8213","relation_version_is_last":true,"title":["乾式吹付け工法と炭素繊維グリットを併用した既存RC柱の耐震補強の可能性について"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:27:42.388326+00:00"}