{"created":"2023-06-19T09:51:02.601543+00:00","id":8034,"links":{},"metadata":{"_buckets":{"deposit":"c70875b5-921e-4571-8745-0a6a1865399c"},"_deposit":{"created_by":3,"id":"8034","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8034"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00008034","sets":["502:505:675:705:706"]},"author_link":["43077","43080","43082","43083","43084","43087","43079","43086","43076","43081","43078","43085"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1998-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"66","bibliographicPageStart":"61","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"坂口, 勝次"}],"nameIdentifiers":[{"nameIdentifier":"43076","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石岡, 泰和"}],"nameIdentifiers":[{"nameIdentifier":"43077","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井戸, 優"}],"nameIdentifiers":[{"nameIdentifier":"43078","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"南山, 龍緒"}],"nameIdentifiers":[{"nameIdentifier":"43079","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The experimental study on the electrostatic cooling was carried out by using a thermography. The DC corona discharge was occurred between a needle and a flat plate electrode under the applied negative high voltage ranged from -7 to -50 kV and the needle-plate gap varied from 15 to 50 mm. The temperature field of the plate electrode was measured by a infrared scanner and the surface temperature distributions of the plate electrode were evaluated and visualized by a thermography system. The local heat transfer coefficients near the stagnation point were enhanced with increasing the applied voltage against the natural convective heat transfer field, while were decreased under the considerably higher voltage.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"43080","nameIdentifierScheme":"WEKO"}],"names":[{"name":"サカグチ, カツジ"}]},{"nameIdentifiers":[{"nameIdentifier":"43081","nameIdentifierScheme":"WEKO"}],"names":[{"name":"イシオカ, ヤスカズ"}]},{"nameIdentifiers":[{"nameIdentifier":"43082","nameIdentifierScheme":"WEKO"}],"names":[{"name":"イド, スグル"}]},{"nameIdentifiers":[{"nameIdentifier":"43083","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ミナミヤマ, タツオ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"43084","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SAKAGUCHI, Katsuji","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"43085","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ISHIOKA, Yasukazu","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"43086","nameIdentifierScheme":"WEKO"}],"names":[{"name":"IDO, Shuguru","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"43087","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MINAMIYAMA, Tatsuo","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部機械工学科"},{"subitem_text_value":"福山大学大学院機械工学専攻:(現)(株)アイメックス"},{"subitem_text_value":"福山大学大学院機械工学専攻:(現)(株)三造試験センター"},{"subitem_text_value":"福山大学工学部機械工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1998-09-01"}],"displaytype":"detail","filename":"KJ00005781404.pdf","filesize":[{"value":"842.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/8034/files/KJ00005781404.pdf"},"version_id":"1a6eea5b-a3ed-4993-be65-101ec4eb6321"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"サーモグラフィ","subitem_subject_scheme":"Other"},{"subitem_subject":"静電冷却","subitem_subject_scheme":"Other"},{"subitem_subject":"可視化","subitem_subject_scheme":"Other"},{"subitem_subject":"熱伝達","subitem_subject_scheme":"Other"},{"subitem_subject":"Thermography","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Electrostatic Cooling","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Visualization","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Heat Transfer","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"サーモグラフィを用いた静電冷却場の可視化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"サーモグラフィを用いた静電冷却場の可視化"},{"subitem_title":"Visualization of Electrostatic Cooling Field by Thermography","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["706"],"pubdate":{"attribute_name":"公開日","attribute_value":"1998-09-01"},"publish_date":"1998-09-01","publish_status":"0","recid":"8034","relation_version_is_last":true,"title":["サーモグラフィを用いた静電冷却場の可視化"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:31:31.077681+00:00"}