{"created":"2023-06-19T09:51:01.840905+00:00","id":8016,"links":{},"metadata":{"_buckets":{"deposit":"05bbff34-8b67-40a7-813e-e201b09cdbb4"},"_deposit":{"created_by":3,"id":"8016","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8016"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00008016","sets":["502:505:675:704"]},"author_link":["42989","42993","42990","42991","42992","42988"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"41","bibliographicPageStart":"31","bibliographicVolumeNumber":"21","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐川, 宏幸"}],"nameIdentifiers":[{"nameIdentifier":"42988","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"占部, 逸正"}],"nameIdentifiers":[{"nameIdentifier":"42989","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The purposes of the radiation measurements are the determination of kinds of radiation, intensity of energy, and direction of incident radiations. It is important for radiation protection to know the information on the positions and directions of incident radiations. From this point of view, a circular scintillation fiber detector composed using position sensitive scintillation fiber sensor was constructed for determination of the directional distribution of radiations incident on a certain point of interest. The response function to get the information on incident direction of radiations was obtained by the experiments and was compared with the results by the Monte Carlo calculation method. The fundamental characteristics of the circular detector were investigated by the irradiation experiments using Cs-137 and it was found that the directional information of radiations fields which have two dimensional distributions could be obtained by the present method.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42990","nameIdentifierScheme":"WEKO"}],"names":[{"name":"サガワ, ヒロユキ"}]},{"nameIdentifiers":[{"nameIdentifier":"42991","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ウラベ, イツマサ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42992","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SAGAWA, Hiroyuki","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"42993","nameIdentifierScheme":"WEKO"}],"names":[{"name":"URABE, Itsumasa","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部電子・電気工学科"},{"subitem_text_value":"福山大学工学部電子・電気工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1997-12-01"}],"displaytype":"detail","filename":"KJ00005781386.pdf","filesize":[{"value":"715.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/8016/files/KJ00005781386.pdf"},"version_id":"11b0b807-2b14-4c48-9635-f6688cf961e4"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"scintillation fiber","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"directional distribution","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"radiation protection","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"response function","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"シンチレーションファイバを用いた放射線方向検出器の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"シンチレーションファイバを用いた放射線方向検出器の開発"},{"subitem_title":"Development of a Scintillation Fiber Detector for Determination of Directional Distribution of Radiations","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["704"],"pubdate":{"attribute_name":"公開日","attribute_value":"1997-12-01"},"publish_date":"1997-12-01","publish_status":"0","recid":"8016","relation_version_is_last":true,"title":["シンチレーションファイバを用いた放射線方向検出器の開発"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:31:48.218286+00:00"}