WEKO3
インデックスリンク
アイテム
熱電対による気温測定について
https://fukuyama-u.repo.nii.ac.jp/records/7937
https://fukuyama-u.repo.nii.ac.jp/records/7937f77a16af-cabc-4b01-8c83-70a45bc7323a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1995-03-01 | |||||
タイトル | ||||||
タイトル | 熱電対による気温測定について | |||||
タイトル | ||||||
タイトル | Air Temperature Measurement Using Thermocouple | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | thermocouple | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | air temperature | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | radiation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | temperature measurement | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
著者名(日) |
小林, 定教
× 小林, 定教 |
|||||
著者名よみ | ||||||
識別子Scheme | WEKO | |||||
識別子 | 42664 | |||||
姓名 | コバヤシ, サダノリ | |||||
著者名(英) | ||||||
識別子Scheme | WEKO | |||||
識別子 | 42665 | |||||
姓名 | KOBAYASHI, Sadanori | |||||
言語 | en | |||||
著者所属(日) | ||||||
値 | 福山大学工学部建築学科 | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | This research, through experiments on influences of the solar radiation and radiation from surrounding objects, which can cause errors during air temperature measurement using a thermocouple, has made clear the effects of the solar-radiation shield length in the vicinity of the temperature sensing element of the thermocouple as well as the effects of the increase in heat transfer rate for the purpose of promotion of heat exchange between the thermocouple and the air. On the basis of the results,the decreasing method of the measurement error, and the measurement accuracy and problems of a ventilated thermocouple type thermometer were examined. Furthermore,because air temperature may change cyclically at a rate of about 1℃ per several seconds, for the purpose of measurement of a value close to the average value, a ventilated thermometer (which is made of copper and cylindrical in shape) whose sensing element has been increased in heat capacity has been manufactured and the accuracy of the thermometer was examined through experiments. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00217655 | |||||
書誌情報 |
福山大学工学部紀要 巻 18, 号 2, p. 35-44, 発行日 1995-03 |