{"created":"2023-06-19T09:50:58.098727+00:00","id":7927,"links":{},"metadata":{"_buckets":{"deposit":"148cffe3-3ffc-4137-ab53-85924c2647eb"},"_deposit":{"created_by":3,"id":"7927","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7927"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00007927","sets":["502:505:675:695:696"]},"author_link":["42642","42643","42644"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1994-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"88","bibliographicPageStart":"83","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小林, 定教"}],"nameIdentifiers":[{"nameIdentifier":"42642","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The heat transfer coefficient of the external surface of the building used for thermal load calculations was proposed by Dr. Watanabe et at. in about 1934. In those days the main purpose of studies focused on heating; recently calculations in respect to cooling have been increasing in importance, calling attention to the heat transfer coefficient in summer in relation to the wind speed. In this paper I studied summer and winter wind speeds based on observation results of a weather station, and from their results estimated and discussed the heat transfer coefficient, leading to a safer thermal load calculation.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42643","nameIdentifierScheme":"WEKO"}],"names":[{"name":"コバヤシ, サダノリ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42644","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KOBAYASHI, Sadanori","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部建築学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1994-09-01"}],"displaytype":"detail","filename":"KJ00005781315.pdf","filesize":[{"value":"483.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/7927/files/KJ00005781315.pdf"},"version_id":"7d6c0256-9c6c-4806-98d7-e151f6a35726"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"wind speed","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"heat transfer coefficient","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"summer","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"気象台観測風速と夏期・冬期の建築物外表面熱伝達率","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"気象台観測風速と夏期・冬期の建築物外表面熱伝達率"},{"subitem_title":"Observed Wind Speed at Weather Station and Heat Transfer Coefficient of External Surface of the Building in Summer and Winter","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["696"],"pubdate":{"attribute_name":"公開日","attribute_value":"1994-09-01"},"publish_date":"1994-09-01","publish_status":"0","recid":"7927","relation_version_is_last":true,"title":["気象台観測風速と夏期・冬期の建築物外表面熱伝達率"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:33:53.015176+00:00"}