{"created":"2023-06-19T09:50:52.616617+00:00","id":7837,"links":{},"metadata":{"_buckets":{"deposit":"ee679b4a-f147-4674-b144-bfb9aa6cdaa0"},"_deposit":{"created_by":3,"id":"7837","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7837"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00007837","sets":["502:505:675:689"]},"author_link":["42184","42187","42188","42189","42186","42191","42185","42183","42190"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"12","bibliographicPageStart":"7","bibliographicVolumeNumber":"14","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"占部, 逸正"}],"nameIdentifiers":[{"nameIdentifier":"42183","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"竹屋, 章史"}],"nameIdentifiers":[{"nameIdentifier":"42184","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中田, 尚"}],"nameIdentifiers":[{"nameIdentifier":"42185","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Considerable attention has been paied to the measurement of UVR in the living environment on account of increasing the level of solar UVR by the stratospheric ozone depletion as well as the widespread utilization of artificial UVR sources in engineering, medicine, and other fields. Some of the fundamental properties of the portable UVR irradiance meter were investigated using a Xenon light source since it seems to be appropriate to get information on radiological protection against UVR. As an example of application of the irradiance meter, a few surveys of UVR in the natural environment were carried out, and it was found that the spectral response and the sensitivity of the sensor had to be improved to determine precisely UVR irradiances in spectral region of interest.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42186","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ウラベ, イツマサ"}]},{"nameIdentifiers":[{"nameIdentifier":"42187","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タケヤ, アキフミ"}]},{"nameIdentifiers":[{"nameIdentifier":"42188","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ナカタ, ヒサシ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42189","nameIdentifierScheme":"WEKO"}],"names":[{"name":"URABE, Itsumasa","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"42190","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TAKEYA, Akifumi","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"42191","nameIdentifierScheme":"WEKO"}],"names":[{"name":"NAKATA, Hisashi","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部電子・電気工学科"},{"subitem_text_value":"福山大学工学部電子・電気工学科:(現)松下電器産業株式会社"},{"subitem_text_value":"福山大学工学部電子・電気工学科:(現)西芝電機株式会社"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1992-01-01"}],"displaytype":"detail","filename":"KJ00005781223.pdf","filesize":[{"value":"394.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/7837/files/KJ00005781223.pdf"},"version_id":"1eca8e24-7697-4740-8626-a13f998bdb2b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ultraviolet radiation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"irradiance","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"natural environment","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"semiconductor detector","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"spectral sensitivity","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"可搬型紫外線照度計の特性試験と環境測定への応用","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"可搬型紫外線照度計の特性試験と環境測定への応用"},{"subitem_title":"Performance Tests of Portable UVR Irradiance Meter and Its Application to Environmental UVR Measurements","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["689"],"pubdate":{"attribute_name":"公開日","attribute_value":"1992-01-01"},"publish_date":"1992-01-01","publish_status":"0","recid":"7837","relation_version_is_last":true,"title":["可搬型紫外線照度計の特性試験と環境測定への応用"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:35:28.192718+00:00"}