{"created":"2023-06-19T09:50:40.194605+00:00","id":7610,"links":{},"metadata":{"_buckets":{"deposit":"f64a4c72-3044-46e8-92ec-ee952d84ad1f"},"_deposit":{"created_by":3,"id":"7610","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7610"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00007610","sets":["502:505:675:677"]},"author_link":["41304","41309","41303","41306","41308","41310","41305","41307","41302"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1980","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"13","bibliographicPageStart":"8","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松井, 松長"}],"nameIdentifiers":[{"nameIdentifier":"41302","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"玉重, 繁良"}],"nameIdentifiers":[{"nameIdentifier":"41303","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"高木, 亨"}],"nameIdentifiers":[{"nameIdentifier":"41304","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"As the transmittance for thermal, radiation of translucent bodies are highlit is difficult to use temperature measurement using infrared techniques. So, in this paper two new methods of non contact temperature measurement for translucent bodies are discussed. One is to measure by radiation thermometer through the translucent body from the source which is set behind the sample, and its temperature is varied twice. The other is conducted by reading the thermal infrared image (thermogram) of temperature targets suspended in the translucent gas.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"41305","nameIdentifierScheme":"WEKO"}],"names":[{"name":"マツイ, マツナガ"}]},{"nameIdentifiers":[{"nameIdentifier":"41306","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タマシゲ, シゲヨシ"}]},{"nameIdentifiers":[{"nameIdentifier":"41307","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タカギ, トオル"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"41308","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MATSUI, Matsunaga","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"41309","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TAMASHIHGE, Shigeyoshi","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"41310","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TAKAGI, Tohru","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Fukuyama University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部電子電気工学科"},{"subitem_text_value":"福山大学工学部電子電気工学科"},{"subitem_text_value":"福山大学工学部電子電気工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1980-01-01"}],"displaytype":"detail","filename":"KJ00005780923.pdf","filesize":[{"value":"621.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/7610/files/KJ00005780923.pdf"},"version_id":"c8f5144c-7a8b-43d7-9c84-e0acaf77048e"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"半透明体の放射温度測定法について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"半透明体の放射温度測定法について"},{"subitem_title":"New Methods of Radiation Thermometry of Translucent Bodies","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["677"],"pubdate":{"attribute_name":"公開日","attribute_value":"1980-01-01"},"publish_date":"1980-01-01","publish_status":"0","recid":"7610","relation_version_is_last":true,"title":["半透明体の放射温度測定法について"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:39:55.871790+00:00"}