{"created":"2023-06-19T09:50:40.152040+00:00","id":7609,"links":{},"metadata":{"_buckets":{"deposit":"15cf1006-174f-43b0-adb2-5081e34e11ac"},"_deposit":{"created_by":3,"id":"7609","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"7609"},"status":"published"},"_oai":{"id":"oai:fukuyama-u.repo.nii.ac.jp:00007609","sets":["502:505:675:677"]},"author_link":["41295","41298","41296","41293","41297","41299","41301","41300","41294"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1980","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"7","bibliographicPageStart":"1","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"福山大学工学部紀要"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高木, 亨"}],"nameIdentifiers":[{"nameIdentifier":"41293","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松井, 松長"}],"nameIdentifiers":[{"nameIdentifier":"41294","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮武, 将浩"}],"nameIdentifiers":[{"nameIdentifier":"41295","nameIdentifierScheme":"WEKO"}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"The reference source of the radiometer for remote sensing should be small and light the emissivity high and the field of view of the optical system wide. In this paper, the theoretical and experimental consideration on emissivity of the cavity type reference source of radiometer for remote sensing is performed. The results are as follows: 1) The simplified equation for calculation of emissivity of cavity type source is introduced. 2) The equation for emissivity of cavity type source at various spectrum and spectral region is obtained, too. 3) Multi-cavity radiator is made for test and the value of its emissivity is 0.989.","subitem_description_type":"Other"}]},"item_1_full_name_7":{"attribute_name":"著者名よみ","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"41296","nameIdentifierScheme":"WEKO"}],"names":[{"name":"タカギ, トオル"}]},{"nameIdentifiers":[{"nameIdentifier":"41297","nameIdentifierScheme":"WEKO"}],"names":[{"name":"マツイ, マツナガ"}]},{"nameIdentifiers":[{"nameIdentifier":"41298","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ミヤタケ, マサヒロ"}]}]},"item_1_full_name_8":{"attribute_name":"著者名(英)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"41299","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TAKAGI, tohru","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"41300","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MATSUI, Matsunaga","nameLang":"en"}]},{"nameIdentifiers":[{"nameIdentifier":"41301","nameIdentifierScheme":"WEKO"}],"names":[{"name":"MIYATAKE, Masahiro","nameLang":"en"}]}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AN00217655","subitem_source_identifier_type":"NCID"}]},"item_1_text_10":{"attribute_name":"著者所属(英)","attribute_value_mlt":[{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Engineering, Fukuyama University"},{"subitem_text_language":"en","subitem_text_value":"Faculty of Industrial Arts, Kyoto Technical University"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"福山大学工学部電子電気工学科"},{"subitem_text_value":"福山大学工学部電子電気工学科"},{"subitem_text_value":"京都工芸繊維大学電子工学科"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"1980-01-01"}],"displaytype":"detail","filename":"KJ00005780922.pdf","filesize":[{"value":"668.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fukuyama-u.repo.nii.ac.jp/record/7609/files/KJ00005780922.pdf"},"version_id":"7190c9c4-7ce7-4f95-95bb-9d150d2ace00"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"リモートセンシング用赤外線放射計の基準放射源の放射率","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"リモートセンシング用赤外線放射計の基準放射源の放射率"},{"subitem_title":"On Emissivity of Reference Source of IR Radiometer for Remote Sensing","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["677"],"pubdate":{"attribute_name":"公開日","attribute_value":"1980-01-01"},"publish_date":"1980-01-01","publish_status":"0","recid":"7609","relation_version_is_last":true,"title":["リモートセンシング用赤外線放射計の基準放射源の放射率"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-06-19T10:39:54.867004+00:00"}